American Journal of Civil Engineering and Architecture
ISSN (Print): 2328-398X ISSN (Online): 2328-3998 Website: https://www.sciepub.com/journal/ajcea Editor-in-chief: Dr. Mohammad Arif Kamal
Open Access
Journal Browser
Go
American Journal of Civil Engineering and Architecture. 2018, 6(1), 38-45
DOI: 10.12691/ajcea-6-1-5
Open AccessArticle

Influence of Interlayer in Timber-Concrete Composite Structures with Threaded Rebar as Shear Connector-Experimental Study

Decroly DJOUBISSIÉ DENOUWÉ1, Adamah MESSAN1, , Eric FOURNELY2, 3 and Abdelhamid BOUCHAIR1, 4

1Institut International d’ingénierie de l’Eau et de l’Environnement (2iE), Laboratoire Eco-Matériaux de Construction (LEMC), 01 BP 594 Ouagadougou 01, Burkina Faso

2Université Clermont Auvergne (UCA), Institut Pascal (IP), BP 10448, F-63000 Clermont-Ferrand, France

3CNRS, UMR 6602, Institut Pascal, F-63171 Aubière, France

4Université Clermont Auvergne (UCA), Institut Pascal (IP), BP 10448, F-63000 Clermont-Ferrand, France;CNRS, UMR 6602, Institut Pascal, F-63171 Aubière, France

Pub. Date: January 26, 2018

Cite this paper:
Decroly DJOUBISSIÉ DENOUWÉ, Adamah MESSAN, Eric FOURNELY and Abdelhamid BOUCHAIR. Influence of Interlayer in Timber-Concrete Composite Structures with Threaded Rebar as Shear Connector-Experimental Study. American Journal of Civil Engineering and Architecture. 2018; 6(1):38-45. doi: 10.12691/ajcea-6-1-5

Abstract

The influence of interlayer on mechanical properties of timber-concrete composite structures using threaded rebar as shear connector is studied. Push-out tests are performed with two configurations of connection between timber and concrete with and without plywood interlayer: one threaded rebar and two cross-threaded rebars. The experimental study consists of push-out tests to characterize the failure modes, the load carrying capacity, and the stiffness for serviceability and ultimate limit states of the connections. The responses of the configurations with interlayer are compared with those without interlayer. The comparisons show that the presence of interlayer reduces the shear strength and the stiffness of the timber-concrete connection with threaded reinforcing bar as connector. Furthermore, based on the experimental results and using nonlinear regression, a mathematical model of each one of configurations of connection is derived which can be easily used with nonlinear FE analyses of Timber-Concrete Connection (TCC) beams.

Keywords:
timber-concrete connection tropical wood threaded rebar interlayer push-out tests

Creative CommonsThis work is licensed under a Creative Commons Attribution 4.0 International License. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/

Figures

Figure of 11

References:

[1]  A. Ceccotti, ‘Composite concrete-timber structures’, Progress in Structural Engineering and Materials, 4 (3), 264-275, 2002.
 
[2]  A. M. P. G. Dias, S. M. R. Lopes, J. G. Van de Kuilen, and H. M. P. Cruz, ‘Load-carrying capacity of timber–concrete joints with dowel-type fasteners’, Journal of Structural Engineering, 133 (5), 720-727, 2007.
 
[3]  M. L. R. Van Der Linden, ‘Timber-concrete composite floor systems’, PhD thesis, Technische Universiteit Delft, Delft, The Netherlands, 1999.
 
[4]  L. F. C. Jorge, S. M. R. Lopes, and H. M. P. Cruz, ‘Interlayer influence on timber-LWAC composite structures with screw connections’, Journal of Structural Engineering, 137 (5), 618–624, 2010.
 
[5]  F. Moshiri, R. Shrestha, and K. Crews, ‘The Effect of Interlayer on the Structural Behaviour of Timber Concrete Composite Utilizing Self-Compacting and Conventional Concretes’, 7 (2), 103-109, 2015.
 
[6]  A. M. P. G. Dias, H. M. P. Cruz, S. M. R. Lopes, and J. W. van de Kuilen, ‘Stiffness of dowel-type fasteners in timber–concrete joints’, Proceedings of the Institution of Civil Engineers - Structures and Buildings, 163 (4), 257-266, 2010.
 
[7]  CEN, ‘EN 408 – Timber structures – Structural timber and glued laminated timber – Determination of some physical and mechanical properties’, European Committee for Standardization, Brussels, Belgium, 2009.
 
[8]  CEN, ‘EN 206-1 - Concrete - Part 1: Specification, performance production and conformity’, European Committee for Standardization, Bruxelles, Belgique, Dec. 2000.
 
[9]  D. D. Djoubissié, A. Messan, E. Fournely, A. Bouchaïr, and F. Tsobnang, ‘Évaluation des caractéristiques mécaniques des connexions par entaille et barre d’acier HA filetée dans les poutres mixtes bois-béton’, Annales du Bâtiment et des Travaux publiques, 68 (2), 6-12, 2016. [in French]
 
[10]  CEN, ‘EN 26891 – Timber structures - Joints made with mechanical fasteners general principles for the determination of strength and deformation characteristics’, European Committee for Standardization, Brussels, Belgium, Aug. 1991.
 
[11]  D. Yeoh, M. Fragiacomo, M. De Franceschi, and A. H. Buchanan, ‘Experimental tests of notched and plate connectors for LVL-concrete composite beams’, Journal of Structural Engineering, 137 (2), 261-269, 2010.
 
[12]  CEN, ‘EN 12512 - Timber structures -Test methods-Cyclic testing of joints made with mechanical fasteners’, European Committee for Standardization, Brussels, Belgium, Mar. 2002.
 
[13]  A. Ceccotti, ‘Timber-concrete composite structures’, Timber engineering, STEP, 2 (E13), 1-16, 1995.
 
[14]  A. M. P. G. Dias, ‘Analysis of the Nonlinear Behavior of Timber-Concrete Connections’, Journal of Structural Engineering, 138 (9), 1128-1137, 2012.
 
[15]  N. Khorsandnia, H. Valipour, and K. Crews, ‘Structural response of timber-concrete composite beams predicted by finite element models and manual calculations’, Advances in Structural Engineering, 17 (11), 1601-1622, 2014.
 
[16]  A. Ceccotti, M. Fragiacomo, and S. Giordano, ‘Behaviour of a timber-concrete composite beam with glued connection at strength limit state’, in Proceedings of 9th World Conference on Timber Engineering (WCTE 2006), Portland, Oregon, USA, 2006.
 
[17]  N. Khorsandnia, H. R. Valipour, and K. Crews, ‘Experimental and analytical investigation of short-term behaviour of LVL–concrete composite connections and beams’, Construction and Building Materials, 37, 229-238, 2012.
 
[18]  E. Lukaszewska, H. Johnsson, and M. Fragiacomo, ‘Performance of connections for prefabricated timber–concrete composite floors’, Materials and structures, 41 (9), 1533-1550, 2008.