Journal of Atmospheric Pollution
ISSN (Print): 2381-2982 ISSN (Online): 2381-2990 Website: https://www.sciepub.com/journal/jap Editor-in-chief: Ki-Hyun Kim
Open Access
Journal Browser
Go
Journal of Atmospheric Pollution. 2020, 8(1), 1-12
DOI: 10.12691/jap-8-1-1
Open AccessArticle

Comparative Assessment of Some Emitted Pollutants’ Concentrations from Selected Fossil Fuel-fired Generators

F.O. Anjorin1, , S. A. Abashi1, F.B. Masok2 and I.M. Essen3

1Department of Physics, University of Jos, Plateau State-Nigeria

2Department of Physics, Plateau State University, Bokkos, Nigeria

3Department of Science Technology, Akwa Ibom State Polytechnic, Ikot Osurua, Ikot Ekpene, Nigeria

Pub. Date: December 18, 2020

Cite this paper:
F.O. Anjorin, S. A. Abashi, F.B. Masok and I.M. Essen. Comparative Assessment of Some Emitted Pollutants’ Concentrations from Selected Fossil Fuel-fired Generators. Journal of Atmospheric Pollution. 2020; 8(1):1-12. doi: 10.12691/jap-8-1-1

Abstract

Fossil fuel-fired generators, though viable alternative sources of energy are a veritable source of several environmental problems. Measurements of gaseous and particle air pollutants is a vital step in exposure assessment and epidemiological studies. In this study, in-situ measurement of some pollutants emitted from selected fossil fuel-fired generators with a wide range of installed capacities (0.9-250kVA), which are under more realistic conditions than the laboratory approach of chamber testing was undertaking using real-time active sampling weekly for one year (November, 2015- October, 2016). The study reveals that the emission rate of CO from 0.9kVA generator, 2.0kVA generator, 50kVA CAT generator, 50kVA Micano generator, 250 kVA generator and 100kVA Micano generator are 93.48 mg/s, 107.67 mg/s, 1.12 mg/s, 12.47 mg/s, 0.08 mg/s and 9.69 mg/s, respectively; Similarly, the emission rate of SO2 from the aforementioned generators are 0.99 mg/s, 1.08 mg/s, 0.07 mg/s, 2.27 mg/s, 0.11 mg/s and 0.93 mg/s, respectively. Furthermore, these generators also emit H2S at the rate of 0.64 mg/s, 0.51 mg/s, 017 mg/s 1.79 mg/s, 0.15 mg/s and 0.92 mg/s, respectively. An insightful analysis of the sampled emission data suggests that emissions from most of the selected generators pose serious potential hazard to the public heath of their immediate neighbourhood.

Keywords:
Fossil Fuel generator emission pollutants microenvironments

Creative CommonsThis work is licensed under a Creative Commons Attribution 4.0 International License. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/

References:

[1]  Selçuk S. (2020). Fuels of the Diesel-Gasoline Engines and Their Properties. Open access peer-reviewed chapter.
 
[2]  Africa Energy Outlook (2014). “A focus on energy prospects in Sub-Saharan Africa”, World Energy Outlook Special Report, International Energy Agency (IEA), Paris.
 
[3]  Ley, K., Gaines, J. and Ghatikar, A. (2015). The Nigerian Energy Sector. An Overview with a Special Emphasis on Renewable Energy, Energy Efficiency, and Rural Electrification, 2nd ed., Deutsche Gesellschaft für Internationale Zusammenarbeit (GIZ) GmbH, Bad Homburg v.d.H.
 
[4]  ASHRAE (2013), Ventilation for Acceptable Indoor Air Quality, Standard 62.1-2013, American Society of Heating, Refrigerating, and Air-Conditioning Engineers, Atlanta, GA.
 
[5]  Mbamali, I, Stanley, A., and Zubairu, I. (2012). Environmental, health and social hazards of fossil fuel electricity generators: A users’ assessment in Kaduna, Nigeria. American International Journal of Contemporary Research, 2(9), 237-254.
 
[6]  Offiong, A. (2003). Assessing the economic and environmental prospect of standby solar powered system in Nigeria. Journal of Applied Sciences and Environmental Management, 7(1), 37-42.
 
[7]  Dimari, G., Abdulrahman, F., Akan, J. and Ogugbuaja, V. (2007). Levels of nitrogendioxide of atmospheric air in Maiduguri, Borno State, Nigeria. Medwell Research Journal of Applied Sciences, 2(7), 846-849.
 
[8]  IARC (2015). Outdoor Air Pollution. International Agency for Research on Cancer (IARC) Monographs on Evaluations of Carcinogenic Risks to Humans, 109:35-109.
 
[9]  Oguntoke, O.O. and Adeyemi, A. (2017). “Degradation of urban environment and human health by emissions from fossil-fuel combusting electricity generators in Abeokuta metropolis, Nigeria”, Indoor and Built Environment, Vol. 26 No. 4, pp. 538-550.
 
[10]  Yesufu, A.L. and Ana, G.R.E.E. (2012). “Electric generator characteristics, pattern of use and non-auditory health effects experienced by commercial workers in Agbowo and Ajibode Area of Ibadan, Nigeria”, Review of Global Medicine and Health care Research,Vol.3, No.2, pp.159-171.
 
[11]  Azodo, A.P. and Adejuyigbe, S.B. (2013). “Examination of noise pollution from generators on the residents of Obantoko, Ogun State, Nigeria”, Asian Journal of Engineering Sciences and Technology, Vol. 3 No. 1, pp. 31-41.
 
[12]  Menkiti, N.U. and Agunwamba, J.C. (2015). “Assessment of noise pollution from electricity generators in a high-density residential area”, African Journal of Science, Technology, Innovation and Development, Vol. 7 No. 4, pp. 306-312.
 
[13]  Adeniran, J.A., Yusuf, R.O., Amole, M.O., Jimoda, L.A. and Sonibare, J.A. (2017), “Air quality impact of diesel back-up generators (BUGs) in Nigeria’s mobile telecommunication base transceiver stations (BTS)”, Management of Environmental Quality: An International Journal, Vol. 28 No. 5, pp. 723-744.
 
[14]  Stuver, S., Alonzo, J.R., Haut, R.C., Burnett, D.B. and Cobb, F.H. (2015), “A comparison of air emission estimation methods for drilling rig emissions”, Environment and Natural Resources Research, Vol. 5 No. 2, pp. 158-164.
 
[15]  Neil E Klepeis, Wayne R Ott, Paul Switzer (2007). Real-time Measurement of outdoor Tobacco Smoke Particles, Journal of the Air and Waste Management Association; Vol.57, Issue 5, Pp.522-534.
 
[16]  Solomon O. Giwa, Collins N. Nwaokocha, Hezekiah O. Adeyemi, (2019) "Noise and emission characterization of off-grid diesel-powered generators in Nigeria", Management of Environmental Quality: An International Journal.
 
[17]  Turner, D.B. (1970): “Workbook of Atmospheric Dispersion Estimates” U.S. Department of Health, Education and Welfare.Pp1-93.
 
[18]  Briggs, G.A., (1972) "Discussion: chimney plumes in neutral and stable surroundings". Atmospheric Environment, 6: 507-510.
 
[19]  IARC (2013a). Diesel and gasoline engine exhausts and some nitroarenes. IARC Monogr Eval Carcinog Risks Hum, 105: 1-704. Available from: http://monographs. iarc.fr/ENG/Monographs/vol105/index.php.
 
[20]  WHO (2016). House hold Air Pollution and Health. WHO Media Centre. Factsheets. Retrieved on 15th February, 2017.
 
[21]  Bhanarkar AD, Rao PS, Gajghate DG, Nema P (2005). Inventory of SO2, PM and toxic metals emissions from industrial sources in Greater Mumbai, India Atmos Environ, 39(21): 3851-64.
 
[22]  Smith SJ, van Aardenne J, Klimont Z, Andres RJ, Volke A, Delgado Arias S (2011). Anthropogenic sulfur dioxide emissions: 1850-2005. Atmos Chem Phys, 11(3):1101-16.
 
[23]  Ozkurt N, Sari D, Akalin N, Hilmioglu B (2013). Evaluation of the impact of SO2 and NO2 emissions on the ambient air-quality in the Çan-Bayramiç region of northwest Turkey during 2007-2008. Sci Total Environ, 456-457: 254-66.
 
[24]  Colls, J. (2002). In: Air pollution, Second Edition, UK. Spon press. UK. 25pp.
 
[25]  Ugwuanyi, J.U. and Obi, F.C. (2002). A Survey of Health Effects on Peasant Farmers in Benue State, Nigeia. International Journal of Environment Studies, 59(6): 665-677.
 
[26]  Watson JG (2002). Visibility: science and regulation. J Air Waste Manag Assoc, 52(6): 628-713.