International Journal of Dental Sciences and Research
ISSN (Print): 2333-1135 ISSN (Online): 2333-1259 Website: https://www.sciepub.com/journal/ijdsr Editor-in-chief: Marcos Roberto Tovani Palone
Open Access
Journal Browser
Go
International Journal of Dental Sciences and Research. 2022, 10(1), 8-12
DOI: 10.12691/ijdsr-10-1-3
Open AccessArticle

The Impact of Adding Different Proportions of Recycled Polyetherether Ketone (PEEK) Particles Fibers as a Denture Repairing Material on Mechanical Properties of Polymethyl Methacrylate

Mohamed Y. Abdelfattah1, 2, and Nouf Al Humayyani3

1Assistant professor of prosthodontics, Faculty of Dentistry, Tanta University, Tanta, Egypt

2Assistant professor of Removable Prosthodontic, Faculty of Dentistry, Taif University, Taif, KSA

3Assistant professor of Fixed Prosthodontic, Faculty of Dentistry, Taif University, Taif, KSA

Pub. Date: February 01, 2022

Cite this paper:
Mohamed Y. Abdelfattah and Nouf Al Humayyani. The Impact of Adding Different Proportions of Recycled Polyetherether Ketone (PEEK) Particles Fibers as a Denture Repairing Material on Mechanical Properties of Polymethyl Methacrylate. International Journal of Dental Sciences and Research. 2022; 10(1):8-12. doi: 10.12691/ijdsr-10-1-3

Abstract

Aim: This laboratory research aimed to assess the impact of addition of various proportions of recycled Polyetherether Ketone (PEEK) particles fibers as a reinforcing filler material on Surface hardness, Surface roughness and Flexural strength of heat cured Polymethyl methacrylate. Materials and methods: .A total of 90 ; specimens of heat polymerized PMMA stored at 37°C water path prior to breaking were divided into 3 main groups; 30 to test surface harndness,30 for surface roughness, and 30 to test Flexural strength with different specifications rather than those which test the surface hardness and surface roughness. For each test, the specimens were subdivided into 3 subgroups; Group I (control group n=10): specimens repaired with auto polymerizing PMMA without any additives. For Group II(n=10), and III(n10), the discarded PEEK particles remained After CAD/CAM milling process, gathered from the device, and recycled to produce particle size of 150 μm using standard sieves of ISO standardization, no 40, 60 and 100. Group II and III specimens repaired with auto polymerizing PMMA strengthened with 1%wt. and 2%wt PEEK particles respectively. Hardness Testing Instrument FH-5 and Laser Abrasion Measurement System LAS-20 devices used to measure surface hardness and surface roughness, respectively. Hardness Testing Instrument Fh-5 was used to measure the Flexural strength. Statistical analyses were done using the One-way ANOVA test. Results: regarding surface hardness, there were significant improvements in Groups II&III. than group I. Insignificant differences in surface roughness between group I&II, and between Group II&III were documented. Conversely, a marked improvement in the surface roughness was recorded between group I&III. Regarding flexural strength, a significant improvement in Group III in comparison with group I or II Conclusion: Addition of PEEK particles fibers as filler material can be used to repair heat polymerized PMMA with improvement of the surface hardness, flexural strength, and decreased surface roughness.

Keywords:
Denture Repair PMMA recycled PEEK particles mechanical properties

Creative CommonsThis work is licensed under a Creative Commons Attribution 4.0 International License. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/

References:

[1]  Takamiya AS, Monteiro DR, Marra J, Compagnoni MA, Barbosa DB. Complete denture wearing and fractures among edentulous patients treated in university clinics. Gerodontology. 2012 Jun; 29(2): e728-34.
 
[2]  Paulino MR, Alves LR, Gurgel BC, Calderon PS. Simplified versus traditional techniques for complete denture fabrication: a systematic review. J Prosthet Dent. 2015 Jan; 113(1): 12-6.
 
[3]  Shalok Bharti, Nilesh D. Ghetiya, Varun Dutta, investigating microhardness and wear behavior of Al5052/ZrO2 surface composite produced by friction stir processing, Materials Today: Proceedings, Volume 44, Part 1, 2021, Pages 52-57.
 
[4]  Hata K, Ikeda H, Nagamatsu Y, Masaki C, Hosokawa R, Shimizu H. Development of Dental Poly(methyl methacrylate)-Based Resin for Stereolithography Additive Manufacturing. Polymers (Basel). 2021 Dec 17; 13(24): 4435.
 
[5]  Gokul, S., S. Ahila, and K.B. Muthu, Effect of E-glass fibers with conventional heat activated PMMA resin flexural strength and fracture toughness of heat activated PMMA resin. Annals of Medical and Health Sciences Research, 2018. 8(3): p. 189-192.
 
[6]  Mishra S, Chowdhary R. PEEK materials as an alternative to titanium in dental implants: A systematic review. Clin Implant Dent Relat Res. 2019 Feb; 21(1): 208-222.
 
[7]  Shrivastava SP, Dable R, Raj APN, Mutneja P, Srivastava SB, Haque M. Comparison of Mechanical Properties of PEEK and PMMA: An In Vitro Study. J Contemp Dent Pract. 2021 Feb 1; 22(2): 179-183. PMID: 34257179.
 
[8]  Aldegheishem A, AlDeeb M, Al-Ahdal K, Helmi M, Alsagob EI. Influence of Reinforcing Agents on the Mechanical Properties of Denture Base Resin: A Systematic Review. Polymers (Basel). 2021 Sep 13; 13(18): 3083.
 
[9]  Stuart B.& Briscoe B.1996. Scratch Hardness Studies of Polyetherether Ketone Polymer37, 3819-3824.
 
[10]  Diaz-Soriano A, Gallo W, Luza S, Munive-Degregori A, Bocanegra R, Mayta-Tovalino F. Knowledge and Awareness of Effective Recycling of Dental Materials and Waste Management among Peruvian Undergraduate Students of Dentistry: A Logistic Regression Analysis. J Int Soc Prev Community Dent. 2020 Jun 15; 10(3): 309-315.
 
[11]  ISO 3310-1: 2016(MAIN) Test sieves — Technical requirements and testing — Part 1: Test sieves of metal wire cloth. ISO: Geneva, Switzerland, 2016.
 
[12]  Walshe GE, Pang L, Flury M, Close ME, Flintoft M. Effects of pH, ionic strength, dissolved organic matter, and flow rate on the co-transport of MS2 bacteriophages with kaolinite in gravel aquifer media. Water Res. 2010 Feb; 44(4): 1255-69.
 
[13]  ISO 20795-1: 2013(MAIN) Dentistry - Base polymers - Part 1: Denture base polymers (ISO 20795-1: 2013 ISO: Geneva, Switzerland,).
 
[14]  Kaiser, S., Clark, S., Nicoletti, D. et al. Optical Properties of a Vibrationally Modulated Solid State Mott Insulator. Sci Rep 4, 3823 (2014).
 
[15]  Raszewski Z, Nowakowska-Toporowska A, Nowakowska D, Więckiewicz W. Update on Acrylic Resins Used in Dentistry. Mini Rev Med Chem. 2021; 21(15): 2130-2137.
 
[16]  Shetty SK, Hasan MS, Zahid M, Suhaim KS, Mohammad F, Fayaz T. Evaluation of Fracture Resistance and Color Stability of Crowns Obtained by Layering Composite Over Zirconia and Polyetheretherketone Copings Before and After Thermocycling to Simulate Oral Environment: An In Vitro Study. J Pharm Bioallied Sci. 2020 Aug; 12(Suppl 1): S523-S529.
 
[17]  Steven M. Kurtz PEEK Biomaterials Handbook, 2nd Edition - March 8, 2019. William Andrew. 246-50.
 
[18]  Burgard N, Kienitz M, Jourdan C, Rüttermann S. The Influence of Modified Experimental Dental Resin Composites on the Initial in Situ Biofilm-A Triple-Blinded, Randomized, Controlled Split-Mouth Trial. Polymers (Basel). 2021 Aug 21; 13(16): 2814.
 
[19]  Montoya C, Kurylec J, Baraniya D, Tripathi A, Puri S, Orrego S. Antifungal Effect of Piezoelectric Charges on PMMA Dentures. ACS Biomater Sci Eng. 2021 Oct 11; 7(10): 4838-4846.
 
[20]  Skupien JA, Valentini F, Boscato N, Pereira-Cenci T. Prevention, and treatment of Candida colonization on denture liners: a systematic review. J Prosthet Dent. 2013 Nov; 110(5): 356-62.
 
[21]  Yu SH, Cho HW, Oh S, Bae JM. Effects of glass fiber mesh with different fiber content and structures on the compressive properties of complete dentures. J Prosthet Dent 2015; 113: 636-644.
 
[22]  Alla RK. Influence of fiber reinforcement on the properties of denture base resins. Journal of Biomaterials and Nanobiotechnology, 2013; 4: 91-97.