American Journal of Environmental Protection
ISSN (Print): 2328-7241 ISSN (Online): 2328-7233 Website: https://www.sciepub.com/journal/env Editor-in-chief: Mohsen Saeedi, Hyo Choi
Open Access
Journal Browser
Go
American Journal of Environmental Protection. 2024, 12(4), 73-76
DOI: 10.12691/env-12-4-4
Open AccessReview Article

Perspective of the Wastewater Evacuation Network and the Treatment Plant of the Diamniadio Urban Pole

Ndiouga CAMARA1, , Alioune LY2, Babacar DIOUF3 and Séni TAMBA2

1Iba Der THIAM University of Thiès, UFR Engineering Sciences, VCN, Thiès, Sénégal

2Polytechnic School of Thiès, Sénégal

3Gaston Berger university of Saint Louis, Polytechnic Institute of Saint Louis., Sénégal

Pub. Date: December 04, 2024

Cite this paper:
Ndiouga CAMARA, Alioune LY, Babacar DIOUF and Séni TAMBA. Perspective of the Wastewater Evacuation Network and the Treatment Plant of the Diamniadio Urban Pole. American Journal of Environmental Protection. 2024; 12(4):73-76. doi: 10.12691/env-12-4-4

Abstract

In Senegal, urban expansion and overpopulation, especially in the capital Dakar, have caused increased problems in terms of housing. To alleviate this scourge, the government of Senegal has decided to create new towns through the Diamniadio Urban Pole and that of Lac Rose to resolve the housing problem but also a set of economic activities. The ambition is to make these Clusters new urban centralities based on social and functional diversity, creating wealth and jobs. The objective of this article is to study the feasibility of the wastewater evacuation network and the treatment plant of the Diamniadio Urban Pole. The approach undertaken initially involves bibliographic research, followed by data collection from project stakeholders, then with the use of Excel software for determining flow rates, calculating and verifying the operating conditions. self-cleaning. Thus, we have achieved a wastewater treatment system with pipes whose sections vary from 250mm to 1000mm. For the operation of the STEP we obtained a pretreatment comprising a screen of 3 m2 of surface, a desander of 4.5 m2 of surface, a degreaser of 190.71m² of surface, a primary decanter of 4768 m3 of volume, a treatment biological comprising an aeration basin of 101,002 m3 and a clarifier of 4,768 m3.

Keywords:
sanitation sizing wastewater treatment plant flow rates Pôle Urbain Diamniadio

Creative CommonsThis work is licensed under a Creative Commons Attribution 4.0 International License. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/

References:

[1]  Special file on Diamniadio (2018) – Role and Mission of the DGPU - Special File on Diamniadio: Role and Missions of the DGPU | MyHouse.
 
[2]  BA, A.; LEYE, S. (2008) – Improvement of the wastewater management system in Rufisque – Engineering final dissertation, ESP, 223 pages.
 
[3]  BESSEDIK, M. (2010) - Water treatment and purification – 370 pages.
 
[4]  WHO (2017) – Sanitation and wastewater - WHO | Sanitation and wastewater (who.int).
 
[5]  OUIZA, H (2017) – Design of a calculation code for the sizing of activated sludge treatment plants – 49 pages.
 
[6]  UVED (2013) – Water treatment – ASTEP teaching module – Introduction (unilim.fr).
 
[7]  FOXTROT International (2012) – Environmental and social impact study – 164 pages.
 
[8]  Water Code (1981) - Law No. 81-13 of March 4, 1981 establishing the Water Code – 15 pages.
 
[9]  Environmental Code (2001) - Law No. 2001-01 of April 12, 2001 on the environmental code – 17 pages.
 
[10]  14HQE (2019) – Wastewater depollution - https://hqe.guidenr.f.
 
[11]  BA, P.; KA, M. (2008) – Liquid sanitation of the Keur Massar resettlement zone – Engineering final dissertation, 164 pages.
 
[12]  Sanitation works (2003) – Booklet n°70 – 419 pages.
 
[13]  SATIN, Marc and SELMI, Béchir. Technical guide to sanitation, Edition le Moniteur, Paris, 1990.
 
[14]  Hygiene Code (1983) - Law No. 2001-01 of April 12, 2001 on the environmental code – 15 pages.