Biomedicine and Biotechnology
ISSN (Print): 2378-5527 ISSN (Online): 2378-5535 Website: https://www.sciepub.com/journal/bb Editor-in-chief: Apply for this position
Open Access
Journal Browser
Go
Biomedicine and Biotechnology. 2014, 2(4), 80-84
DOI: 10.12691/bb-2-4-3
Open AccessArticle

Evaluation of the Average Weighting Factor in Thin Layer Irradiation by Bremsstrahlung

A.V. Belousov1, , U.A. Bliznyuk2 and A.P. Chernyaev1

1Physical department, M.V. Lomonosov Moscow State University, Moscow, Russia

2Nuclear research institute named by D.V. Skobeltcin

Pub. Date: November 23, 2014

Cite this paper:
A.V. Belousov, U.A. Bliznyuk and A.P. Chernyaev. Evaluation of the Average Weighting Factor in Thin Layer Irradiation by Bremsstrahlung. Biomedicine and Biotechnology. 2014; 2(4):80-84. doi: 10.12691/bb-2-4-3

Abstract

Photon radiation passing through biological tissues induces streams of secondary particles. Photonuclear reactions produce radiation with high linear energy transfer values and, consequently, a high value of radiation weighting factor (wR). When irradiating thin layers, secondary electrons don’t have enough time to transfer all of their energy to the matter of the layer, due to their large range. The heavy particles produced in this process transfer their energy to the matter almost at the location of their production. As a result, the secondary heavy particles may greatly contribute in the equivalent dose, despite the low probability of photonuclear reactions. In this article, the average value of wR is assessed for all types of radiation induced by bremsstrahlung when thin layers are irradiated.

Keywords:
relative biological effectiveness bremsstrahlung spectra radiation weighting factor photonuclear reaction products

Creative CommonsThis work is licensed under a Creative Commons Attribution 4.0 International License. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/

References:

[1]  Zackrisson B., Johansson B. and Ostbergh P. Relative biological effectiveness of high-energy photons (upto 50 MV) and electrons (50 MeV), Rad. Res., 1991,128.192-196.
 
[2]  Zackrisson B., Karlsson M. Relative biological effectiveness of 50 MV X-rayson jejuna crypt survival in vivo, Rad. Res., 1992,113. 112-114.
 
[3]  Gudowska I., Brahme A., Andreo P. ttal. Calculation of absorbed dose and biological effectiveness from photonuclear reactions in a bremsstrahlung beams of end point 50 MeV, Physical Medical Biology, 1999. 2099-2125.
 
[4]  Spurny F., Johansson L., Satherberg A. et al.The contribution of secondary heavy particles ti the absorbed dose from high-energy photons beams. Physical Medical Biology, 1996, 41. 2643-2656.
 
[5]  Tilikidis A., Lind B., Nafstadius P., Brahme A. An estimation of the relative biological effectiveness of 50 MV bremsstrahlung beams by microdosimetric techniques, Physical Medical Biology, 1996, 41. 55-69.
 
[6]  ICRP, 2010. Conversion Coefficients for Radiological Protection Quantities for External Radiation Exposures, ICRP Publication 116, Annuals 40 (2-5).
 
[7]  Agostinelli S., Allison J., Amako K. et al. GEANT4 – a simulation toolkit, Nulcear Instruments and Methods in Physics Research A, 2003, 506. 250-303.
 
[8]  Allison J., Amako K., Apostolakis J. GEANT4 developments and applications, IEEE Transactions in Nuclear Science, 2006, 53 (1). 270-278.
 
[9]  Cirrone C.A.P., Guttone G., Di Rosa F. et al. Validation of the GEANT4 electromagnetic photon cross-sections for elements and compounds, Nulcear Instruments and Methods in Physics Research A, 2010, 608. 315-322.
 
[10]  Poon E., Verhaegen F. Accuracy of the photon and electron physics in GEANT4 for radiotherapy applications, Medical Physics, 2005, 32. 1696-1711.
 
[11]  Cortes-Giraldo M.A., Quesada J.M., Gallardo M.I., Capote R. GEANT4 application for the simulation of the head of a Siemens Primus linac, AIP Conference Proceedings Series, 2009, 1231. 209-210.
 
[12]  Faddegon B.A., Kawrakow I., Kubyshin Y. et al. The accuracy of EGSnrc, GEANT4 and PENELOPE Monte Carlo systems for the simulation of electron scatter in external beam radiotherapy, Physics in Medicine and Biology, 2009, 54 (20). 6151-6163.
 
[13]  Larsson S., Svensson R., Godowska I., Ivanchenko V., Brahme A. Radiation transport calculations for 50 MV photon therapy beam using the Monte Carlo code GEANT4, Radiation Protection Dosimetry, 115 (1-4). 503-507.
 
[14]  http://www.ge.infn.it/geant4/examples/medical_linac/