American Journal of Civil Engineering and Architecture
ISSN (Print): 2328-398X ISSN (Online): 2328-3998 Website: https://www.sciepub.com/journal/ajcea Editor-in-chief: Dr. Mohammad Arif Kamal
Open Access
Journal Browser
Go
American Journal of Civil Engineering and Architecture. 2014, 2(2), 60-63
DOI: 10.12691/ajcea-2-2-1
Open AccessArticle

Effect of End Sill in the Performance of Stilling Basin Models

H.L. Tiwari1, and Arun Goel2

1Department of Civil Engg Maulana Azad National Institute of Technology, Bhopal, India

2Department of Civil Engg National Institute of Technology, Kurukshetra, India

Pub. Date: March 13, 2014

Cite this paper:
H.L. Tiwari and Arun Goel. Effect of End Sill in the Performance of Stilling Basin Models. American Journal of Civil Engineering and Architecture. 2014; 2(2):60-63. doi: 10.12691/ajcea-2-2-1

Abstract

An experimental investigation on effect of end sill on the performance of stilling basin models for a non circular pipe outlet has been presented in this research paper. New physical models for non circular pipe outlet stilling basin have been developed in the laboratory. These newly models were tested in the laboratory for three Froude numbers namely Fr = 1.85, 2.85 and 3.85. The new models are developed by changing the geometry of end sill of same height while keeping the other configuration of stilling basin geometry same. Total twenty one test runs of one hour duration each were performed. The performance of the models was compared by performance number (PN) to evaluate the performance. The study indicated that, for the given Froude number range, the triangular end sill of height 1d with width 1d (slope 1V:1H), is performing better in comparison to other shapes of the end sill for the given flow conditions. The study also confirmed that there is a significant effect of the shape of the end sill geometry on the performance of the stilling basin models.

Keywords:
end sill froude number physical model performance number stilling- basin

Creative CommonsThis work is licensed under a Creative Commons Attribution 4.0 International License. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/

Figures

Figure of 6

References:

[1]  Alikhani A, Behrozi, R., Fathi, M., “Hydraulic Jump in Stilling Basin with Vertical End Sill,” International Journal of Physical Sciences, 5 (1), 25-29, 2010.
 
[2]  Bradley, J.N., Peterka, A. J., “Hydraulic Design of Stilling Basins,” Journal of A.S.C.E., Hydraulic Engg, 83 (5), 1401-1406, 1957.
 
[3]  Fiala, J. R. , Maurice, L. A., “Manifold Stilling Basins,” Journal of A.S.C.E., Hydraulic Div, 87 (4), 55-81, 1961
 
[4]  Keim, S.R., “Contra Costa Energy Dissipator,” Journal of A.S.C.E., Hydraulic Division, 88 (2), 109-122, 1962.
 
[5]  Flammer, G.H, Skogerboe, G.V., Wei, C.Y., Rasheed, H., “Closed Conduit to Open Channel Stilling Basin,” Journal of A.S.C.E., Irrigation and Drainage Div, 96 (1), 1-11, 1970.
 
[6]  Vollmer, E., Khader, M.H.A., “Counter Current Energy Dissipator for Conduit Outlets,” International J. of Water Power, 23 (7), 260-263, 1971.
 
[7]  Garde, R .J. Saraf, P.D., Dahigaonkar, D.J., “Evolution of Design of Energy Dissipator for Pipe Outlets,” J. of Irrigation & Power, 41 (3), 145-154, 1986.
 
[8]  Verma, D.V.S, Goel, A., “Stilling Basins for Outlets Using Wedge Shaped Splitter Blocks,” ASCE Journal of Irrigation and Drainage Engineering, 126 (3), 179-184, 2000.
 
[9]  Tiwari, H.L., Goel, A. and Gahlot, V.K., “Experimental Study of Sill Controlled Stilling Basins for Pipe Outlet,” International Journal of Civil Engg. Research, 2 (2), 107-117, 2011.
 
[10]  Elevatorski, Edward, A., “Hydraulic Energy Dissipators,” McGraw Hill Book Co. Inc., New York. 1959.
 
[11]  Verma, D.V.S., Goel, A., “Development of Efficient stilling basins for pipe outlets,” ASCE Journal of Irrigation and Drainage Eng. 129 (3), 194-200, 2003.
 
[12]  Noshi, H.M., “Energy Dissipation near the Bed Downstream End sill,” IHAR Proceeding, 1-8, 1999,
 
[13]  Mohammed, T.A., Noor, M.J.M.M., Huat, B.K., Ghazali A.H., Yunis, T.S., “Effect of Curvature and End Sill Angle on Scouring at Downstream of a Spillway,” International Journal of Engg and Technology, 1 (1), 96-101, 2004.
 
[14]  Gogus, M., Cambazoglu, M. K., Yazicioglu, M., “Effect of Stilling Basin End sills on the River Bottom Erosion,” Advances in Hydro Science and Engineering, VI, 2006.
 
[15]  H. L. Tiwari, V. K. Gahlot and Seema Tiwari, “Reduction of Scour depth downstream of pipe outlet stilling basin using end sills”, International Journal of Engineering Sciences. 2 (7), 20-25, July 2013.