Article citationsMore >>

Brakstad F., “Accurate determination of double bond position in mono-unsaturated straight-chain fatty acid ethyl esters from conventional electron impact mass spectra by quantitative spectrum-structure modeling.” Chem. Int. Lab. Syst., 19, 87-100, 1993.

has been cited by the following article:

Article

GC-FID Method Development and Validation Parameters for Analysis of Palm Oil (Elaeis guineensis Jacq.) Fatty Acids Composition

1Lipids Analysis Laboratory, IRAD Specialized Centre for Oil Palm Research of La Dibamba, Douala-Cameroon

2Laboratory of Genetics and Plant Improvement, University of Yaounde 1, Department of Plant Biology, Yaounde-Cameroon

3University of Yaounde 1, Higher Teachers’ Training College, Department of Biological Sciences, Yaounde-Cameroon

4Centre Africain de Recherche sur Bananiers et Plantains (CARBAP), Njombé-Cameroun

5Institute of Agricultural Research for Development (IRAD), S. W. Regional Centre, Ekona-Cameroon


Research in Plant Sciences. 2014, Vol. 2 No. 3, 53-66
DOI: 10.12691/plant-2-3-2
Copyright © 2014 Science and Education Publishing

Cite this paper:
Ntsomboh-Ntsefong Godswill, Ngando-Ebongue Georges Frank, Maho-Yalen Josian Edson, Youmbi Emmanuel, Bell Joseph Martin, Ngalle-Bille Hermine, Tabi-Mbi Kingsley, Likeng-Li-Ngue Benoit Constant, Nsimi-Mva Armand. GC-FID Method Development and Validation Parameters for Analysis of Palm Oil (Elaeis guineensis Jacq.) Fatty Acids Composition. Research in Plant Sciences. 2014; 2(3):53-66. doi: 10.12691/plant-2-3-2.

Correspondence to: Ntsomboh-Ntsefong  Godswill, Lipids Analysis Laboratory, IRAD Specialized Centre for Oil Palm Research of La Dibamba, Douala-Cameroon. Email: ntsomboh@yahoo.fr

Abstract

The variety of available techniques and analytical methods applied in laboratories calls for the need of defining the scope, range of application and quality of information obtained using each of them with reference to internationally agreed standards. Of these techniques, Gas Chromatography with Flame Ionization Detector (GC-FID) is most used in fatty acids analysis. Method development and validation is useful for GC and other analytical procedures. This paper outlines the importance of method validation and elaborates on typical validation parameters with special reference to their application in the analysis of fatty acids of palm oil. The first section presents background information on stages in analytical method processing, quantitative and qualitative analysis, GC and its use in the analysis of lipid extracts. Critical components for a method are highlighted such as sampling, sample preparation (FAME derivatization), instrument analysis conditions and method standardization. Validation characteristics like Specificity, Linearity and range, Accuracy, Precision, LOD, LOQ, Robustness, Ruggedness and System suitability are presented in the last section with a brief view on some statistical methods used in method validation. It is hoped that this review will facilitate the work of analysts and the scientific community by enhancing efficient method development and validation which matches international standards.

Keywords