Article citationsMore >>

Kern M, Sasse M, Wolfart S. Ten-year outcome of three-unit xed dental prostheses made from monolithic lithium disilicate ceramic. J Am Dent Assoc. 2012; 143: 234-240.

has been cited by the following article:

Article

Correlation between Luting Agent Curing Mode and Ceramic Thickness on Color of Ceramic Veneers

1Clinical Dental Sciences Department, College of Dentistry, Princess Nourah Bint Abdulrahman University, Riyadh, Saudi Arabia

2Dental Interns, College of Dentistry, Princess Nourah Bint Abdulrahman University, Riyadh, Saudi Arabia


International Journal of Dental Sciences and Research. 2020, Vol. 8 No. 2, 52-55
DOI: 10.12691/ijdsr-8-2-5
Copyright © 2020 Science and Education Publishing

Cite this paper:
Alhanoof Aldegheishem, Reem Aljubair, Halima Samara, Elzahraa Abd. Eldwakhly. Correlation between Luting Agent Curing Mode and Ceramic Thickness on Color of Ceramic Veneers. International Journal of Dental Sciences and Research. 2020; 8(2):52-55. doi: 10.12691/ijdsr-8-2-5.

Correspondence to: Alhanoof  Aldegheishem, Clinical Dental Sciences Department, College of Dentistry, Princess Nourah Bint Abdulrahman University, Riyadh, Saudi Arabia. Email: asaldegheishem@pnu.edu.sa

Abstract

Objective: The aim of the study is to assess the influence of ceramic thickness and type of luting agent on color variation of IPS empress press ceramic system. Methodology: Thirty ceramic specimens were prepared and divided according to thickness into 2 groups of 15 each (G1: 1mm, and G2: 2mm thick). Specimens were further subdivided according to the type of luting agent into 3 subgroups (5 each) and seated on a dark background of resin composite. Two resinous cements namely; Rely X (3M ESPE) and G-CEM LinkAce were used for 2 subgroups, whereas the third subgroup received no cement and served as a control (C1: 1mm thick, C2: 2mm thick). Evaluation of the variation of color parameters was determined using the spectrophotometer (Spectra). The evaluation of the color parameters was determined using the CIE Lab system of colors using a dental colorimeter. Two-way analysis of variance (ANOVA) was used for the statistical analysis using SPSS version 21.0. Results: Spectra photometer was significantly affected by the ceramic thickness (P=0.000). Additionally, the use of the 2 mm thickness ceramic provoked the ΔE values. The highest mean ΔE was seen in control 2mm group (2.05). Whereas, the lowest ΔE was found in Control 1mm (0.65). The luting agent seems to have no effect on mean color difference (P=0.115). Conclusion: The color difference (ΔE) was significantly affected by different ceramic thickness (P=0.000), while the luting agent seems to have no influence on mean color difference. The color changes that determined are clinically acceptable.

Keywords