Trebuňa F., Šimčák F., Bocko J. and Pástor M., “Application of vibro-isolation elements in supporting piping systems of compressor stations” inProceeding of the 3rd International Conference on Modelling of Mechanical and Mechatronic systems, Zemplínska Šírava, Slovak Republic, September 22-24, 2009, 489-495.

has been cited by the following article:

Article

Modal Analysis of Exhaust Fan Impeller

1Department of Applied Mechanics and Mechatronics, Technical University of Košice,Slovakia


American Journal of Mechanical Engineering. 2013, Vol. 1 No. 7, 457-460
DOI: 10.12691/ajme-1-7-61
Copyright © 2013 Science and Education Publishing

Cite this paper:
Róbert Huňady, František Šimčák, František Trebuňa. Modal Analysis of Exhaust Fan Impeller. American Journal of Mechanical Engineering. 2013; 1(7):457-460. doi: 10.12691/ajme-1-7-61.

Correspondence to: Róbert  Huňady, Department of Applied Mechanics and Mechatronics, Technical University of Košice,Slovakia. Email: robert.hunady@tuke.sk

Abstract

The paper deals with determination of modal parameters of exhaust fan impeller. The aim of performed analysis was to investigate whether resonance is the cause of excessive operational vibration of the fan. The paper describes results of experimental measurement by which the natural frequencies of non-rotating impeller were determined. The resonance frequencies and mode shapes during the rotation were estimated by using Finite Element simulation.

Keywords