Article citationsMore >>

Eriksen F, Charoenpatrawut J, Zaman S, Thomasen IN, Bathum L. Hemolysis may cause false negative results and underdiagnosis of celiac disease when measuring anti-tissue transglutaminase antibodies in serum by immunoassays. Scandinavian journal of clinical and laboratory investigation. 2018 May 14: 1-2.

has been cited by the following article:

Article

False-negative IgA Anti-tissue Transglutaminase

1Department of Pediatrics, University Hospital of Setif; Setif 1 University, Algeria

2Genetic, Cardiovascular & Nutritional Diseases Laboratory; Setif-1 University, Algeria

3Central Laboratory, CAC Hospital of Setif; Setif-1 University, Algeria


International Journal of Celiac Disease. 2018, Vol. 6 No. 3, 87-88
DOI: 10.12691/ijcd-6-3-2
Copyright © 2019 Science and Education Publishing

Cite this paper:
Nada Boutrid, Hakim Rahmoune, Mounira Amrane. False-negative IgA Anti-tissue Transglutaminase. International Journal of Celiac Disease. 2018; 6(3):87-88. doi: 10.12691/ijcd-6-3-2.

Correspondence to: Nada  Boutrid, Department of Pediatrics, University Hospital of Setif; Setif 1 University, Algeria. Email: nadaboutrid@gmail.com

Abstract

The expanding knowledge about gluten-related autoimmunity led to a serology-based step-wised approach to diagnose celiac disease that might be misleading due to laboratory techniques. We present a rare case associating initial false-negative anti-transglutaminase IgA antibodies while CD was confirmed by IgG anti-transglutaminase and subsequent duodenal biopsy.

Keywords