Article citationsMore >>

Trina Roy, Abhijit Chandra. Computational Modeling and Analysis of Latest Commercially Available Coronary Stents During Deployment, Science Direct. Procedia Materials Science 5(2014) 2310-2319.

has been cited by the following article:

Article

In a Preliminary Simulation Data, Stent with Thinnest Strut Beta Crystalline Titanium Gold Alloy (β-Ti-Au) Outperforms Typical Implants

1School of Medicine, Florida International University Herbert Wertheim College of Medicine, Miami, Florida, USA

2University of Miami, PRISM and Foote Fellow Program, Coral Gables, Florida, USA


American Journal of Biomedical Research. 2018, Vol. 6 No. 2, 46-52
DOI: 10.12691/ajbr-6-2-3
Copyright © 2018 Science and Education Publishing

Cite this paper:
Adam Au, Sahil Verma. In a Preliminary Simulation Data, Stent with Thinnest Strut Beta Crystalline Titanium Gold Alloy (β-Ti-Au) Outperforms Typical Implants. American Journal of Biomedical Research. 2018; 6(2):46-52. doi: 10.12691/ajbr-6-2-3.

Correspondence to: Adam  Au, School of Medicine, Florida International University Herbert Wertheim College of Medicine, Miami, Florida, USA. Email: xbywqtz@gmail.com

Abstract

Background: Large volume of data support the overall safety of coronary stents for cardiovascular disease. Yet, one cannot lose sight of their shortcomings such as restenosis; hence stents continue to evolve in lattices, materials, and drugs. Studies outlining the successful use of titanium gold alloy stents to counter these issues are lacking. Methods: In this analysis we obtained available historical manufacturing records on routinely used stents to compare to two revolutionary titanium-gold alloy stents. By using a 3D CAD finite element analysis space, each stent type was tested for flexibility, rigidity, and radial forces. Except for lengths and diameter, each type was held to their own strut geometry and thickness. Our analysis focused on using Von Mises Stress and resulting deformation or expansion. Our assessments were performed by using discrete changes and Pearson’s chi-squared statistics to obtain significance of our findings. Three lengths: 15mm,27.5mm and 40mm were tested for each type. Comparisons were obtained from the mean percentage length or diameter (3.5mm) changes. Results: β-Ti-Au alloy in our hexagonal mesh was significantly more expansive (78.29 percent gain in diameter under 7 atm. than Orsiro Hybrid (the baseline). p < 0.001. The best performance in vertical crush testing was obtained from our second original structure, titanium – gold alloy stent 1 (0.8 percent vs control). Nobori was the most longitudinally flexible in that testing category but was closely matched by beta titanium – gold alloy (1.97 percent vs 2.19 percent) with promus PREMIER’s performance serving as the zero-reference point. In radial strength testing, our opened and closed titanium-gold structures first and second designs respectively came second and third to Orsiro (10.03 percent >9.09 percent >7.80 percent). Maximum changes in displacements, 0.19 and 0.25. Both values were significant. (95% CI 0.11-0.27, 0.17-2.33). Conclusion: Routine use of Titanium in coronary stents has been hindered by its low density, elastic modulus and strength; contrary these results suggest that by mixing titanium with gold and on the right structure the alloy can be constructed with a thin strut for percutaneous coronary intervention.

Keywords