<?xml version="1.0" encoding="UTF-8"?>
<records>
<record>
<language>eng</language>
<publisher>Science and Education Publishing</publisher>
<journalTitle>World Journal of Analytical Chemistry</journalTitle>
<publicationDate>2013-08-13</publicationDate>
<volume>1</volume>
<issue>1</issue>
<startPage>49</startPage>
<endPage>53</endPage>
<doi>10.12691/wjac-1-4-1</doi>
<publisherRecordId>WJAC2013141</publisherRecordId>
<documentType>article</documentType>
<title language="eng">Solid Phase Extraction of Silicate by Sorption on Modified Magnetite Nanoparticles and Spectrophotometric Determination</title>
<authors>
<author>
<name>Mohammad Ali Karimi</name>
<email>ma_karimi43@yahoo.com</email>
<affiliationId>1</affiliationId>
<affiliationId>2</affiliationId>
</author>
<author>
<name>Abdolhamid Hatefi-Mehrjardi</name>
<affiliationId>2</affiliationId>
<affiliationId>2</affiliationId>
</author>
<author>
<name>Sayed Zia Mohammadi</name>
<affiliationId>2</affiliationId>
<affiliationId>3</affiliationId>
</author>
<author>
<name>Alireza Mohadesi</name>
<affiliationId>3</affiliationId>
<affiliationId>3</affiliationId>
</author>
<author>
<name>Javad Yarahmadi</name>
<affiliationId>3</affiliationId>
</author>
<author>
<name>Asghar Askarpour Kabir</name>
<affiliationId>3</affiliationId>
</author>
<author>
<name>Havva Mahmoodian</name>
<affiliationId>3</affiliationId>
</author>
<author>
<name>Shahla Nezhad Khorasani</name>
<affiliationId>3</affiliationId>
</author>

</authors>
<affiliationsList>
<affiliationName affiliationId="1">Department of Chemistry, Payame Noor University, Tehran, Iran</affiliationName>







</affiliationsList>
<abstract language="eng">A new adsorbent of<b> </b>alumina-coated magnetite nanoparticles (ACMNPs) modified with cetyltrimethyl ammonium bromide (CTAB) was prepared for the separation/preconcentration of trace silicate from water samples and then determined by spectrophotometry method. Silicate was determined based on the molybdenum blue method, which monitored at ¦Ë<SUB>max</SUB> of 830 nm. MNPs and ACMNPs characterized by SEM and VSM. Under the optimal experimental conditions, the preconcentration factor, detection limit, linear range and relative standard deviation of silicate were 70 (for 350 mL of sample solution), 0.040 ¦Ìg mL<SUP>?1</SUP>, 0.8-7.0 ¦Ìg mL<SUP>?1</SUP> and 2.2 % (for 5.0 ¦Ìg mL<SUP>-1</SUP>, n=7), respectively. The method was applied to the separation/preconcentration and determination of silicate in tap water, river water and seawater samples with satisfactory results.</abstract>
<fullTextUrl format="pdf">http://pubs.sciepub.com/wjac/1/4/1/wjac-1-4-1.pdf</fullTextUrl>
<keywords language="eng"><keyword>separation/preconcentration</keyword>
<keyword>silicate</keyword>
<keyword>modified alumina-coated magnetite nanoparticles (ACMNPs)</keyword>
<keyword>molybdenum blue method</keyword>
</keywords>
</record>
</records>
