﻿<?xml version="1.0" encoding="UTF-8"?>
<records>
  <record>
    <language>eng</language>
    <publisher>Science and Education Publishing</publisher>
    <journalTitle>International Journal of Dental Sciences and Research</journalTitle>
    <eissn>2333-1259</eissn>
    <publicationDate>2018-03-19</publicationDate>
    <volume>6</volume>
    <issue>2</issue>
    <startPage>48</startPage>
    <endPage>52</endPage>
    <doi>10.12691/ijdsr-6-2-6</doi>
    <publisherRecordId>IJDSR2018626</publisherRecordId>
    <documentType>article</documentType>
    <title language="eng">The Correlation between Peri-implant Bone Density and the Biological Implant Stability: A Two Years Follow-up</title>
    <authors>
      <author>
        <name>Walid S. Salem</name>
        <affiliationId>1</affiliationId>
        <affiliationId>2</affiliationId>
      </author>
      <author>
        <name>Mohamed R. Mahmoud</name>
        <affiliationId>3</affiliationId>
      </author>
      <author>
        <name>Wael M. Zakaria</name>
        <email>dr.wael.zakaria@qudent.org</email>
        <affiliationId>3</affiliationId>
      </author>
      <author>
        <name>Yasser A. Araby</name>
        <affiliationId>3</affiliationId>
      </author>
    </authors>
    <affiliationsList>
      <affiliationName affiliationId="1">Department Oral and Maxillofacial Radiology, Beni Suef University, Egypt</affiliationName>
      <affiliationName affiliationId="3">Department of Prosthetic Dental Sciences, College of Dentistry, Qassim University, Saudi Arabia</affiliationName>
    </affiliationsList>
    <abstract language="eng">Objective: The aim of this study was to assess the correlation between the peri-implant bone density and the biological stability around dental implants. Materials and Methods: A total of 56 implants were placed in the mandibular canine area of 28 patients to retain mandibular overdentures. The assessment of bone density changes was obtained through Cone-Beam Computed Tomography (CBCT) and the assessment of implant stability was obtained through Resonance Frequency Analysis (RFA) at loading time, and after 6, 12, 24 months. Results: RFA measurement showed a mean of 67.5± 5.8 ISQ at loading time and a mean of 71.3±5.5 ISQ after 24 months. Bone density around the implants showed a mean of 683.48±78.63 HU at loading time, and a mean of 722.24±58.4 HU after 24 months. These increases were statistically significant (p?0.05). Conclusion: The biological implant stability as measured using the Resonance Frequency Analysis (RFA) and the peri-implant bone density as measured using Cone Beam Computed Tomography (CBCT) showed a significant moderate positive correlation.</abstract>
    <fullTextUrl format="pdf">http://pubs.sciepub.com/ijdsr/6/2/6/ijdsr-6-2-6.pdf</fullTextUrl>
    <keywords language="eng">
      <keyword>biological stability</keyword>
      <keyword>bone density</keyword>
      <keyword>resonance frequency analysis</keyword>
      <keyword>cone beam computed tomography</keyword>
    </keywords>
  </record>
</records>