<?xml version="1.0" encoding="UTF-8"?>
<records>
<record>
<language>eng</language>
<publisher>Science and Education Publishing</publisher>
<journalTitle>American Journal of Mechanical Engineering</journalTitle>
<publicationDate>2013-11-17</publicationDate>
<volume>1</volume>
<issue>7</issue>
<startPage>339</startPage>
<endPage>342</endPage>
<doi>10.12691/ajme-1-7-37</doi>
<publisherRecordId>AJME20131737</publisherRecordId>
<documentType>article</documentType>
<title language="eng">Comparison of the Cylindricity Deviation Using Different Evaluation Methods</title>
<authors>
<author>
<name>Miroslav Dovica</name>
<email>miroslav.dovica@tuke.sk</email>
<affiliationId>1</affiliationId>
</author>
<author>
<name>Alexander Végh</name>
<affiliationId>1</affiliationId>
</author>

</authors>
<affiliationsList>
<affiliationName affiliationId="1">Technical University, Mechanical Engineering Faculty, Department of Biomedical Engineering and Measurement, Košice, Slovakia</affiliationName>

</affiliationsList>
<abstract language="eng">This paper deals with the measurement and the evaluation of cylindricity deviation of the rotational symmetrical workpiece. Coordinate Measuring Machine (CMM) with X-Ray tomography was used for the measurement. For the evaluation of the cylindricity deviation, we applied standard Gaussian cylinder. Data obtained by the measurement is compared using the VG Studio and Calypso software. At the end of this paper, the experimental data is presented.</abstract>
<fullTextUrl format="pdf">http://pubs.sciepub.com/ajme/1/7/37/ajme-1-7-37.pdf</fullTextUrl>
<keywords language="eng">cylindricity deviation measurementcoordinate measurement machineX-ray</keywords>
</record>