﻿<?xml version="1.0" encoding="UTF-8"?>
<records>
  <record>
    <language>eng</language>
    <publisher>Science and Education Publishing</publisher>
    <journalTitle>American Journal of Biomedical Research</journalTitle>
    <eissn>2328-3955</eissn>
    <publicationDate>2015-07-29</publicationDate>
    <volume>3</volume>
    <issue>3</issue>
    <startPage>45</startPage>
    <endPage>52</endPage>
    <doi>10.12691/ajbr-3-3-3</doi>
    <publisherRecordId>AJBR2015333</publisherRecordId>
    <documentType>article</documentType>
    <title language="eng">Effect of Variations in Post-set Temperature and Monomer Concentration on Self-cure Acrylic Surface Candidal Growth: An In-vitro Study</title>
    <authors>
      <author>
        <name>Nimra Tahir</name>
        <affiliationId>1</affiliationId>
      </author>
      <author>
        <name>Faisal Moeen</name>
        <email>faisalmoeen_is@yahoo.com, faisal.moeen@riphah.edu.pk</email>
        <affiliationId>1</affiliationId>
      </author>
      <author>
        <name>Muhammad Humza Bin Saeed</name>
        <affiliationId>2</affiliationId>
      </author>
    </authors>
    <affiliationsList>
      <affiliationName affiliationId="1">Department of Dental Materials, Islamic International Dental College, Riphah University, Islamabad</affiliationName>
      <affiliationName affiliationId="2">Department of Community Dentistry, Riphah International University</affiliationName>
    </affiliationsList>
    <abstract language="eng">Objectives: To identify the effect of variations in power-liquid ratio and post-set temperature on water absorption and residual monomer concentration on growth of Candida albicans on self-cure denture base resins. Methodology: 60 self-cured acrylic discs (39 x 4mm) were made and divided into 3 groups each having 20 specimens. Group 1 consisted of discs fabricated at a powder-liquid ratio of 5.1:2.8 as recommended by the manufacturer. Groups 2 and 3 constituted specimens with variations in post-set temperatures and powder-liquid ratios respectively. Specimens from group 2 were soaked in four water baths at temperatures of 37°C, 47°C, 57°C and 67°C for 24 hours. Specimens from the temperature-controlled group 3 were fabricated at four different powder-liquid ratios by increasing monomer liquid volume by 10%, 15%, 20% and 25%. The acrylic discs from control groups 1 and 3 were soaked at a constant temperature of 37°C for 24 hours. Residual monomer leeched out from disc into water was analyzed using Ultraviolet spectrophotometer. The variations in water absorption and Candidal growth were recorded. Results: Linear regression analysis was used to analyze the results. A moderately positive correlation was calculated for the association between powder-liquid ratio and Candidal growth (r = 0.67, p &lt; 0.001) suggesting Candidal growth is higher at increased powder-liquid ratios having low monomer content. The correlation between the Candidal growth and the post-set temperatures was found to be moderately negative (r = -0.41 p &lt; 0.001), indicating a decrease in Candidal cells on increasing post-set soaking temperatures. Conclusions: Candidal growth follows a positive linear relation with a decreasing powder-liquid ratio having cells increasing with an increase in liquid monomer content. Candidal growth follows a negative linear relation with post-set temperature soaking with cells decreasing with an increase in temperature.</abstract>
    <fullTextUrl format="pdf">http://pubs.sciepub.com/ajbr/3/3/3/ajbr-3-3-3.pdf</fullTextUrl>
    <keywords language="eng">
      <keyword>polymethyl-methacrylate (PMMA)</keyword>
      <keyword>self-cure acrylic resin</keyword>
      <keyword>residual monomer</keyword>
      <keyword>candida albicans</keyword>
      <keyword>water absorption</keyword>
    </keywords>
  </record>
</records>