American Journal of Nursing Research. 2019, 7(3), 387-391
DOI: 10.12691/ajnr-7-3-20
Open AccessArticle

Effect of Positive End Expiratory Pressure on Central Venous Pressure in Mechanically Ventilated Patients

Khaled Mohammed Al-Sayaghi1, 2, , Hassnaa Eid Shaban Mosa3, Masouda Hassan Atrous4, Azza Hamdi El-Soussi5, Ahmed Youssef Ali6 and Sahar Hossni El-shenawi5

1Critical Care and Emergency Nursing, College of Nursing, Taibah University, KSA

2Critical Care and Emergency Nursing, Faculty of Medicine and Health Sciences, Sana'a University, Yemen

3Medical Surgical Nursing, Faculty of Nursing, Menoufia University, Egypt

4Critical Care and Emergency Nursing, Faculty of Nursing, Jouf University, KSA

5Critical Care and Emergency Nursing, Critical Care and Emergency Nursing Department, Faculty of Nursing, Alexandria University, Egypt

6Anesthesia and Surgical Intensive Care, Faculty of Medicine, Alexandria University, Egypt

Pub. Date: April 24, 2019

Cite this paper:
Khaled Mohammed Al-Sayaghi, Hassnaa Eid Shaban Mosa, Masouda Hassan Atrous, Azza Hamdi El-Soussi, Ahmed Youssef Ali and Sahar Hossni El-shenawi. Effect of Positive End Expiratory Pressure on Central Venous Pressure in Mechanically Ventilated Patients. American Journal of Nursing Research. 2019; 7(3):387-391. doi: 10.12691/ajnr-7-3-20

Abstract

Background: Central venous pressure (CVP) monitoring remains in common use as an index of circulatory filling and cardiac preload. Positive end-expiratory pressure (PEEP) in mechanically ventilated patients can affect CVP via increasing intra-thoracic pressure. Critical care nurses should be able to measure the CVP competently and identify the factors affecting its readings. Aim: The current study was conducted to determine the effect of PEEP on the CVP readings in mechanically ventilated patients. Methods: a descriptive design used in this study. A convenient sample of 200 adult critically ill patients of both sex, hemodynamically and respiratory stable, having a central venous catheter (CVC) in place, and attached to a mechanical ventilator and pulse oximeter were included in the study. The patient's baseline CVP was recorded while the patient connected to the mechanical ventilator, then the patients were temporary disconnected from the mechanical ventilator and the CVP measured again without the effect of PEEP. Results: About 40% of the study sample aged 45 to 64 years, 52.5% were males, 50 % suffered from respiratory disorders, and 49% were overhydrated. Eighty eight percent of the study sample was on PEEP levels between 5 to < 10 cmH2O. The CVP readings while the patients connected to MV were higher than CVP reading while the patients without PEEP, but these differences were not significant. Conclusion: CVP readings are not significant affected by the PEEP up to 15 cmH2O. The CVP can be reliably measured while patients are connected to MV. Recommendations: Measurement of CVP can be obtained while the patient is connected to MV.

Keywords:
PEEP mechanical ventilation central venous pressure critically ill patients

Creative CommonsThis work is licensed under a Creative Commons Attribution 4.0 International License. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/

References:

[1]  Vincent J, Rhodes A, Perel A, Martin G, Rocca G, Vallet B, et al. Clinical review: update on hemodynamic monitoring - a consensus of 16. Critical Care 2011; 15(4): 229.
 
[2]  Saugel B, Malbrain M, Perel A. Hemodynamic monitoring in the era of evidence-based medicine. Critical Care 2016; 20: 401.
 
[3]  Dan M, Varghese L. Correlation between Peripheral Venous Pressure and Central Venous Pressure Monitored by CVP Manometer: an Observational Study. International Journal of Scientific and Research Publications 2015; 5(8).
 
[4]  Huygh J, Peeters Y, Bernards J, Malbrain M. Hemodynamic monitoring in the critically ill: an overview of current cardiac output monitoring methods. Research 2016; 5: 2855.
 
[5]  Roger C, Muller L, Riou B, Molinari N, Louart B, Kerbrat H, Tebou J, Lefrant J. Comparison of different techniques of central venous pressure measurement in mechanically ventilated critically ill patients. British Journal of Anaesthesia 2017; 118(2): 223.
 
[6]  De Backer D, Vincent J. Should we measure the central venouspressure to guide fluid management? Ten answers to 10 questions. Critical Care 2018; 22: 43.
 
[7]  Shojaee M, Sabzghabaei A, Alimohammadi H, Derakhshanfar, Amini A, Esmailzadeh B. Effect of Positive End-Expiratory Pressure on Central Venous Pressure in Patients under Mechanical Ventilation. Emergency 2017; 5 (1): e1.
 
[8]  Das R, Lee Y, Oh S. The Determinants Of Mean Central Venous Pressure For Shock Patients. J Clin Trial Cardiol. 2018; 5(2): 1-5.
 
[9]  Alviar L, Miller P, McAreavey D, Katz J, Lee B, Moriyama B, et al. Positive Pressure Ventilation in the Cardiac Intensive Care Unit. J Am Coll Cardiol 2018; 72(13): 1532-53.
 
[10]  Chen H, Xu M, Yang Y, Chen K, Xu J, Zhang Y, et al. Effects of increased positive end-expiratory pressure on intracranial pressure in acute respiratory distresssyndrome: a protocol of a prospective physiological study. BMJ 2016; 6(11): e012477.
 
[11]  Shubin H, and Will M. Routine central venous catheterization for management of critically ill patients. IN: Ingelfinger F, Ebert R, Finland M, and Rolman A, editor. Controversy in Internal Medicine. W.B. Sauanders Co, Piladelphia, 1974, 177-184.
 
[12]  Kumar BU. Handbook of mechanical ventilation. 2nd ed. Jaypee Brothers Medical Pub, New Delphi, 2016.
 
[13]  Finkelmeier BA. Cardiothoracic surgical nursing. 2nd ed. Lippincott, Philadelphia, 2000, 277-88.
 
[14]  Kirchhoff K, Piano M, Patel M. Arterial pressure readings: variations with positions and transducer level. Nursing Research 1984; 33(6): 343-5.
 
[15]  Pennington L, Smith C. Leveling when monitoring central blood pressure: an alternative method. Heart Lung 1980; 9(6): 1053-9.
 
[16]  Calow L, Pieper B. Effect of back rest elevation on central venous pressure in pediatric cardiac surgery. Nursing Research 1998; 38(6): 336-8.
 
[17]  Martin G, Olivier W, David B, Stefan B. Basic concepts of heart-lung interactions during mechanical ventilation. Swiss Med Wkly. 2017; 147: w14491.
 
[18]  Backhaus R, Torka E, Ertl M, Kirzinger L, Wagner A, Baldaranov D, et al. Influence of Positive End-Expiratory Pressure Ventilation on Cerebral Perfusion and Cardiac Hemodynamics. Journal of Depression and Anxiety 2017; (6): 4: 285.
 
[19]  Kuhn B, Bradley A, Dempsey T, Puro A, Adams J. Management of mechanical ventilation in decompensated heart failure. J. Cardiovasc. Dev. Dis. 2016; 3 (4): 33.
 
[20]  Sen O, Doventas Y. Effects of different levels of end-expiratory pressure on hemodynamic, respiratory mechanics and systemic stress response during laparoscopic cholecystectomy. Rev Bras Anestesiol. 2017; 67(1): 28-34.